S-Series Two-stage Air Compressors​

  1. Home
  2. »
  3. Product
  4. »
  5. S-Series Two-stage Air Compressors​
two-stage air compressor 2

S-Series Two-stage Air Compressors​

  • Rated Pressure: 0.8-1.3 MPa, 8-13 bar, 116-188 psi
  • Air Flow@ Outlet: 4.2-75.32 m³/min
  • Power: 30-355 kW, 40-476 hp

Features of the two-stage air Compressor

● Self-developed variable speed technology which increases efficiency and offers energy savings.

● SKF Bearing , GHH RAND / Rotor Comp Air End(optional)

●  Enhanced stability and reliability as well as cost-effectiveness.

● Reduce power consumption by around 35% compared to traditional frequency machines.

Core Component Highlights of the two-stage air Compressor

Air End

● Adopt two-stage independent compression ;

● The pressure ratio is equal over both stages as well as having a lower compression speed, which helps improve volumetric efficiency;

● Oil mist spray cooling is used between the stages to make the entire compression process close to isothermal compression and improve the compression insulation efficiency;

● The two-stage rotors are directly driven by the bevel gear respectively, and the compression transmission efficiency is high;

● The large diameter and low speed of the rotors reduce stress on the bearings, thus lengthening their life span as well as any other components. 

air end

High- Protection Level Motor

The main motor is an IP55 high-efficiency energy-saving permanent magnet motor carefully selected according to the application of the air compressor. (other IP level available)

All meet the national energy efficiency standards, F-class insulation, B-class temperature rise, effectively prevent the entry of dust,SKF heavy-duty bearings ensure continuous trouble-free operation for a long time.

motor

Ultra-Quiet Centrifugal Cooling Fan

● Ultra-quiet large air volume, frequency conversion cooling fan;

 

● Low loss, low noise, low power consumption;

 

● High heat transfer rate, quiet and efficient.

centrifugal-fan-

Customized large cooling system

The cooling system is designed to keep the temperature at a constant level. Its features include an increased radiator surface area with rust and corrosion resistant coatings, as well as a low oil temperature which prevents carbon deposits and high-temperature occurrences.

 

Additionally, the use of large variable frequency fans or centrifugal fans in units over 75 kW ensures even heat distribution, low noise levels, and large air volume.

cooler-768x768
ModelPower
(kW/HP)
Rated Working
Pressure
(bar)
Free Air Delivery
(m3/min)
Dimensions
(mm)
Weight
(kg)
Outlet Pipe
Diameter
NXS-22F
NXS-22V
22 / 3084.11675*1080*1400720DN40
103.4
132.7
NXS-30F
NXS-30V
30 / 4085.91675*1080*1400780DN40
105.3
133.9
NXS-37F
NXS-37V
37 / 5087.51675*1080*1400820DN40
106.8
135.5
NXS-45F
NXS-45V
45 / 6089.22460*1540*17051800DN50
108.1
136.7
NXS-55F
NXS-55V
55 / 75811.92460*1540*17051860DN50
1011.2
138
NXS-75F
NXS-75V
75 / 100815.72460*1540*17051960DN50
1014.6
1311.5
NXS-90F
NXS-90V
90 / 120819.12460*1540*17052800DN65
1015.5
1314.5
NXS-110F
NXS-110V
110 / 150821.63015*1680*18053100DN65
1019
1317.2
NXS-132F
NXS-132V
132 / 175825.73015*1680*18053300DN65
1024.5
1318.7
NXS-160F
NXS-160V
160 / 215831.43500*1980*20503800DN80
1030.4
1324.6
NXS-185F
NXS-185V
185 / 250836.53500*1980*20504100DN80
1031.9
1326.5
NXS-200F
NXS-200V
200 / 270840.73865*2050*23004800DN100
1035.8
1330.4
NXS-220F
NXS-220V
220/300845.33865*2050*23005100DN100
1038.9
1335
NXS-250F
NXS-250V
250 / 335850.53865*2050*23005600DN100
1044.1
1338.2
NXS-280F
NXS-280V
280 / 375854.74100*2200*23006300DN125
1049.2
1343.7
NXS-315F
NXS-315V
315 / 420860.34100*2200*23006500DN125
1054.1
1349
NXS-355F
NXS-355V
355 / 475866.44100*2200*23007700DN125
1063.7
1353.2

Note:

Model number remarks: “F” as fixed speed, “V” as VSD. Due to the potentially different rotation speeds of motors, the air flow rates of fixed speed represent the minimum in the range (i.e 30kW 8 bar 5.67m³/min), while VSD can reach the maximum at full loading.

Standard voltage in 380V (+/-10%), 50Hz +/-2% and available for customized voltage 220/380/440/460V/60Hz.

In cases of elevated altitudes, extreme temperatures, excessive humidity, heavy dust exposure, or any other challenging operational environments, we can offer tailored product designs to meet your specific needs. Customization is available to align with your unique requirements.

Search

Contact Us

Installation Diagram for Two-stage Screw Compressor(Variable Speed Rotary Screw Type)

S-Series Two-stage Air Compressors​

Looking for the Best Compressed Air Solution for your industry?

Share your requirements for expert evaluation (multilingual support).

Develop customized solution, considering options such as IP level, air end and parts, screen language, remote control, appearance, voltage and temperature adaptation, etc.

Start production after order confirmation (standard production time: 20-25 days).

Conduct rigorous quality testing before shipping.

Lifelong technical support, original maintenance parts support, and up to 10-year warranty on the air end.

Frequently Asked Questions

Low Pressure Two-stage VSD Screw Air Compressor is a type of air compressor that uses two stages of compression to produce compressed air. It is equipped with a Variable Speed Drive (VSD) system that allows for energy-efficient operation and can adjust the compressor’s speed to match the air demand. This type of compressor is commonly used in industries such as automotive, food and beverage, and pharmaceuticals.

A two-stage air compressor works by compressing air in two stages. In the first stage, air is compressed to an intermediate pressure and then sent to a second cylinder where it is compressed to the final desired pressure. This allows for higher efficiency and greater power output compared to a single-stage compressor.

First, check the refrigerant pressure and ensure that the cold dryer and suction dryer are working properly. Also, make sure that the air compressor’s storage tank and filters are draining properly. Then, open the valves between the storage tank, dryers, filters, and the air compressor to ensure smooth airflow.

Next, check the oil level and look for any leaks or obstacles around the machine. If it’s a water-cooled machine, open the cooling water valve and pump, and confirm that the water pressure is normal. Finally, turn on the power and start the machine. If it has been idle for a while, start it a few times before running it continuously to avoid unnecessary malfunctions such as overheating or overload.